Choose Colour style

Description


RAY3000 Precious Metal Analyzer
20230418/5cc8688076bd2a62f738dfb9d6eb8d18.jpg
Performance and configuration
Analysis Range0.01% to 99.99%
Accuracy0.1%
Sample FormSolid, Powder, Liquid
Tube Voltage5KV ~ 50KV
High Voltage Power Supply0 ~ 50KV
Camera
HD Camera
FiltersSelectable Customized Swtiches
Detector TypeProportional counter tube
Multichannel AnalyzerMulti channel simulation
Sample Chamber Size325*430*90(mm)
Test Time5 ~ 60 secs
Measuring ElementAu, Ag, Pt, Pd, Cu...
Analysis SoftwareQualitative & Quantitavtive Analysis Software
External Dimensions
430*430*350(mm)
Weight33KG

Instruments Environmental Requirements
Ambient Temperature

5℃ ~ 38℃ (Suggested that in air conditioning room)

Relative Humidity15% ~ 90%
Power RequirementsAC220V ± 5V, 50/60Hz



EDS3900EDS3900C


20230418/021530fa7e0dd1f73154321e10911b2f.jpg


20230418/e7cf4909c0e6a9dca8ce0745f4bfee80.jpg

Performance and configuration
Analysis Range0.01% to 99.99%
Accuracy0.1%  0.05%  To 0.1%
Sample FormSolid, Powder, Liquid
Tube Voltage5KV ~ 50KV
High Voltage Power Supply0 ~ 50KV
Light Control Current
0 mu A ~ 1000 mu A
Camera
HD Camera
FiltersSelectable Customized Swtiches
Detector TypeProportional Counter tube
Multichannel AnalyzerMulti channel simulationDigital multichannel
Sample Chamber Size310*280*60(mm)480*320*70(mm)
Test Time5 ~ 60 secs
Measuring Element

Au, Ag, Pt, Pd, Cu...

Analysis SoftwareQualitative & Quantitavtive Analysis Software
External Dimensions
400*430*350(mm)500*340*230(mm)
Weight33KG20KG

Instruments Environmental Requirements
Ambient Temperature

5℃ ~ 40℃ (Suggested that in air conditioning room)

Relative Humidity15% ~ 90%
Power Requirements

AC220V ± 5V, 50/60Hz

No high power electromagnetic and vibration interference sources nearby




EDS7700EDS7700T
20230418/74e5facb68a2d2f5c7a71aef1fa822cf.jpg


20230418/eb0c36e34dccc5a7c654a06c2c4f9506.jpg

Performance and configuration
Analysis Range1 PPM to 99.99%
Accuracy0.03%  (Au>96%)0.01%  (Au>96%)
Sample FormSolid, Powder, Liquid
Tube Voltage5KV ~ 50KV
High Voltage Power Supply0 ~ 50KV
Light Control Current
0 mu A ~ 1000 mu A
Camera
HD Camera
FiltersSelectable Customized Swtiches
Detector TypeSi-pin (Amptek, USA)SDD (Amptek, USA)
Resolution145 + 5 ev135 + 5 ev
Multichannel AnalyzerKEY -DMCP
Sample Chamber Size380*380*60(mm)
Test Time5 ~ 60 secs
Measuring Element

72 elements from sodium (Na) touranium (U) between all the elements

Analysis SoftwareKEY-FP Qualitative & Quantitavtive Analysis Software
External Dimensions
480*480*390(mm)
Weight38KG

Instruments Environmental Requirements
Ambient Temperature

5℃ ~ 40℃ (Suggested that in air conditioning room)

Relative Humidity15% ~ 90%
Power Requirements

AC220V ± 5V, 50/60Hz

No high power electromagnetic and vibration interference sources nearby




EDS8800EDS8800T
3253b8ec85461d76f6675bcda47eba74.jpg
Performance and configuration
Analysis Range1 PPM to 99.99%
Accuracy0.03%  (Au>96%)0.01%  (Au>96%)
Sample FormSolid, Powder, Liquid
Tube Voltage5KV ~ 50KV
High Voltage Power Supply0 ~ 50KV
Light Control Current
0 mu A ~ 1000 mu A
Camera
HD Camera
FiltersSelectable Customized Swtiches
Detector TypeSi-pin (Amptek, USA)SDD (Amptek, USA)
Resolution145 + 5 ev135 + 5 ev
Multichannel AnalyzerDigital multichannel
Sample Chamber Size310*270*80(mm)
Test Time3 ~ 60 secs
Measuring Element

72 elements from sodium (Na) touranium (U) between all the elements

Analysis SoftwareKEY-FP Qualitative & Quantitavtive Analysis Software
External Dimensions
460*390*360(mm)
Weight38KG

Instruments Environmental Requirements
Ambient Temperature

5℃ ~ 40℃ (Suggested that in air conditioning room)

Relative Humidity15% ~ 90%
Power Requirements

AC220V ± 5V, 50/60Hz

No high power electromagnetic and vibration interference sources nearby



EDS9800EDS9800T
20230418/220004ba0ae4c3b5cd5e5bfccd6c7cde.jpg
Performance and configuration
Analysis Range1 PPM to 99.99%
Accuracy0.03%  (Au>96%)0.01%  (Au>96%)
Sample FormSolid, Powder, Liquid
Tube Voltage5KV ~ 50KV
High Voltage Power Supply0 ~ 50KV
Light Control Current
0 mu A ~ 1000 mu A
Camera
HD Camera
FiltersSelectable Customized Swtiches
Detector TypeSi-pin (Amptek, USA)SDD (Amptek, USA)
Resolution145 + 5 ev135 + 5 ev
Multichannel AnalyzerDigital multichannel
Sample Chamber Size310*270*90(mm)
Test Time3 ~ 60 secs
Measuring Element

72 elements from sodium (Na) touranium (U) between all the elements

Analysis SoftwareKEY-FP Qualitative & Quantitavtive Analysis Software
External Dimensions
480*440*368(mm)
Weight36KG

Instruments Environmental Requirements
Ambient Temperature

5℃ ~ 40℃ (Suggested that in air conditioning room)

Relative Humidity15% ~ 90%
Power Requirements

AC 220V ± 10V, or AC 110V ± 10V, 50/ 60 Hz

No high power electromagnetic and vibration interference sources nearby